ICRP Task Group 108 has recently published two reports about optimisation in digital radiography — ICRP Publication 154: Optimisation of Radiological Protection in Digital Radiology Techniques for Medical Imaging and ICRP Publication 160: Practical Aspects in Optimisation of Radiological Protection in Digital Radiography, Fluoroscopy, and CT. This webinar addresses important points of both reports through presentations by Task Group members. Attendees will have an opportunity to participate through a moderated Q&A session.
Participants who attend at least 50% of the workshop will receive a Certificate of Attendance via email within 48 hours of the event.
Use of medical imaging continues to increase, making the largest contribution to the exposure of populations from artificial sources of radiation worldwide. The principle of optimisation of protection is that ‘the likelihood of incurring exposures, the number of people exposed, and the magnitude of their individual doses should all be kept as low as reasonably achievable (ALARA), taking into account economic and societal factors’. Optimisation for medical imaging involves more than ALARA – it requires keeping individual patient exposures to the minimum necessary to achieve the required medical objectives. In other words, the type, number, and quality of images must be adequate to obtain the information needed for diagnosis or intervention. Dose reductions for imaging or x-ray-image-guided procedures should not be used if they degrade image quality to the point where the images are inadequate for the clinical purpose. The move to digital imaging has provided versatile acquisition, post-processing, and presentation options, and enabled wide and often immediate availability of image information. However, because images are adjusted for optimal viewing, the appearance may not give any indication if the dose is higher than necessary. Nevertheless, digital images provide opportunities for further optimisation, and allow the application of artificial intelligence methods. Optimisation of radiological protection for digital radiology (radiography, fluoroscopy, and computed tomography) involves selection and installation of equipment, design and construction of facilities, choice of optimal equipment settings, day-to-day methods of operation, quality control programmes, and ensuring that all personnel receive proper initial and career-long training. The radiation dose levels that patients receive also have implications for doses to staff. As new imaging equipment incorporates more options to improve performance, it becomes more complex and less easily understood, so operators have to be given more extensive training. Ongoing monitoring, review, and analysis of performance is required that feeds back into the improvement and development of imaging protocols. Several different aspects relating to optimisation of protection that need to be developed are set out in this publication. The first is collaboration between radiologists/other radiological medical practitioners, radiographers/medical radiation technologists, and medical physicists, each of whom have key skills that can only contribute to the process effectively when individuals work together as a core team. The second is appropriate methodology and technology, with the knowledge and expertise required to use each effectively. The third relates to organisational processes which ensure that required tasks, such as equipment performance tests, patient dose surveys, and review of protocols, are carried out. There is wide variation in equipment, funding, and expertise around the world, and the majority of facilities do not have all the tools, professional teams, and expertise to fully embrace all the possibilities for optimisation. Therefore, this publication sets out broad levels for aspects of optimisation that different facilities might achieve, and through which they can progress incrementally: Level D – preliminary; Level C – basic; Level B – intermediate; and Level A – advanced. Guidance from professional societies can be invaluable in helping users to evaluate systems and aid in adoption of best practice. Examples of systems and activities that should be in place to achieve the different levels are set out. Imaging facilities can then evaluate the arrangements they already have, and use this publication to guide decisions about the next actions to be taken in optimising their imaging services.
Digital radiology is playing an increasingly important role in medicine worldwide. The use of computed tomography (CT) has risen dramatically in recent decades, and makes up approximately half of the population dose from medical exposures in many parts of the world. In addition, ever more complex interventional procedures guided by fluoroscopy are replacing more invasive surgical techniques, thus substituting risks from surgery with lesser ones from radiation. These radiological techniques provide significant health benefits, but the associated radiation dose levels need to be kept commensurate with the benefit accrued. Key factors in achieving this are ensuring that examinations are only carried out when they can contribute to management of a patient’s condition, and that the radiological protection aspects for all exposures are optimised. The latter is the subject of the present publication.Digital imaging data contribute versatility in image acquisition, post-processing, and presentation, and provide opportunities for optimisation. However, unlike their analogue equivalent, images acquired digitally may not provide an indication that a dose is too high or images are not collimated, so there are new problems that have to be addressed. In Publication 154, three fundamental requirements for taking the optimisation process forward were described: (i) the need for collaboration between radiologists, other radiological medical practitioners, radiographers/medical radiation technologists, medical physicists, and managers; (ii) access to the appropriate methodology, technology, and expertise; and (iii) provision of organisational processes which ensure that tasks, such as equipment performance tests, patient dose surveys, and reviews of protocols, are carried out and acted upon. A high-level requirement is the integration and use of decision sciences, and harmonisation of these optimisation processes across multi-specialty clinical teams and equipment types within healthcare systems.This publication contains information on practical methods needed to carry optimization forward for different imaging techniques: radiography, fluoroscopy (and fluoroscopically guided interventional procedures), and CT. Many features of digital equipment allow dose levels to be reduced while still maintaining adequate image quality for the clinical task. Staff need to understand the relationship between the different selectable options to use the features effectively. However, there is a wide range in available equipment and training around the world. Provision ranges from clinics with simple radiographic units to specialist hospitals with complex state-of-the-art eqipment. Some countries have established communities of medical physicists, while in other countries, there is little or no medical physics support. This presents challenges in communicating requirements for optimisation. This publication addresses these challenges by providing information for facilities within broad categories linked to optimisation arrangements already in place: Level D – preliminary; Level C – basic; Level B – intermediate; and Level A – advanced. It is hoped that through this approach, radiology teams will be able to plan strategies for introducing optimisation techniques that are appropriate for their own facilities and equipmuent.
13:00
|
![]() |
IntroductionDavid Sutton (University of Dundee, UK) |
13:05
|
![]() |
A Framework for Building OptimisationColin Martin (University of Glasgow, UK) |
13:20
|
![]() |
How QA Programme and Tools Enhance Optimisation and Continual ImprovementMika Kortesniemi (HUS Diagnostic Center, Helsinki University Hospital, Finland) |
13:30
|
![]() |
Data Analysis and Artificial Intelligence in OptimisationJohn Damilakis (University of Crete, Greece) |
13:40
|
![]() |
Applying the ICRP Optimisation Framework: Practical Approaches in Radiography, Fluoroscopy and Interventional ProceduresJenia Vassileva (Roentgen Foundation, Bulgaria) |
13:50
|
Applying the ICRP Optimisation Framework: Practical Approaches in Computed Tomography (MDCT, DECT and Photon-counting)Irene Hernandez-Giron (School of Physics, University College Dublin, Ireland) |
14:00
|
![]() |
Optimisation Tools for Imaging Paediatric and Pregnant PatientsKimberly Applegate (University of Kentucky, USA) |
14:10
|
Q&A |